CTI

I/O Systems

Products Overview

The SIGMATEK I/O Systems open all possibilities – whether in the control cabinet or directly in the field. DIAS stands for “Distributed Automation System”. All series, S-DIAS (IP20), P-DIAS (IP67) and X-DIAS (IP20) have a very high package density, are simple to use and can be flexibly combined.

 
 

P-DIAS

No products were found matching your selection.

S-DIAS

SR 022 –

DC motor current controller (+12-30 V DC/0-3.5 A) 1 incremental encoder input 1 digital input +5 V 2 digital inputs +24 V For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

SRO 021 –

2 safe relay outputs (max. +30 V DC/6 A) Closing (NO) SIL 3/PL e, Cat. 4 To use the SRO 021 in an application, a Safety CPU module is required.   For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

SRO 022 –

2 safe relay outputs (max. +230 V AC/6 A) Closing (NO) SIL 3/PL e, Cat. 4     To use the SRO 022 in an application, a Safety CPU module is required.   For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

SSI 021 –

Provides values from 2 SSI absolute value encoders (up to 32 bits), Safety and standard CPU Safe monitoring of the speed, position and absolute value violation SIL 3/PL e, Cat. 4     The 2-channel Safety function is implemented by processing the position values in the Safety core (2 micro controllers with cross communication). To use the SSI 021 in an application, a Safety CPU module is required.   For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

ST 011 –

Frequency output for controlling stepper or servo motor power component (RS422) Incremental encoder interface with ABR analysis for regulated mode 2 digital inputs for reference motion and monitoring the end positions 2 digital optic coupler outputs (1 back-readable output) For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

ST 151 –

+50 V DC/5 A continuous current Full step, half step and micro step (up to 64x) 1 brake chopper 1 incremental encoder input RS485/TTL switchable 2 enable inputs with STO function 2 latch / digital input for the reference profile and for monitoring the end positions For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

STO 081 –

8 safe digital outputs (+24 V DC/2 A) SIL 3/PL e, Cat. 4 To use the STO 081 in an application, a Safety CPU module is required.   For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

SV 141 –

1x VARAN In (RJ45) 4x VARAN Out (RJ45) +24 V DC supply connectible to VARAN Out ports For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

SV 142 –

1x VARAN In (Tyco Mini I/O) 4x VARAN Out (Tyco Mini I/O) +24 V DC supply connectible to VARAN Out ports For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

TO 081 –

8 digital short-circuit proof outputs (+24 V DC/0.5 A) For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

TO 127 –

12 digital short-circuit proof outputs (+24 V DC/1.7 A) divided into 3 groups Primary side (+5 V DC) and secondary side (+24 V DC) separated via optical coupler   Both sides of the outputs (primary and secondary) are separated according to the safety-relevant requirements of the Institute for Occupational Safety (in accordance with application class 3, pollution degree 2).   For the S-DIAS system, EPLAN-Makros are available for simple integration into the control cabinet.

TO 161 –

16 digital short-circuit proof outputs (+24 V DC/0.5 A) divided into 2 groups For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

TS 041 –

4 transonic encoder Evaluation of path measuring systems such as ultrasound path sensors from MTS and Balluff (DPI/IP protocol) Contact and wear-free recoding of measurement values using ultrasound For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

TS 051 –

5 transonic encoder Evaluation of path measuring systems such as ultrasound path sensors from MTS and Balluff (DPI/IP protocol) Contact and wear-free recoding of measurement values using ultrasound For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

VA 011 –

 VARAN real-time analysis of the transmission response 1x VARAN In (RJ45), 1x VARAN Out (RJ45) and 1x Gigabit Ethernet 10/100/1000 VARAN service tool for data evaluation The VA 011 can be connected to a free VARAN port during operation. If a port is no longer available, an existing VARAN bus connection can be simply disconnected and the analyzer inserted.   For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.   *Wireshark and the "fin" logo are registered trademarks of the Wireshark Foundation

VBC 021 –

Connection from two independent VARAN bus systems to the field level VARAN system 1: 1x VARAN In (RJ45), 2x VARAN Out (RJ45) VARAN system 2: 1x VARAN In (RJ45), 1x VARAN Out (RJ45) Connection to the company network via the IP port (RJ45) Connected bus systems are synchronized

VBC 121 –

For connecting VARAN and EtherCAT bus systems VARAN: 1x VARAN In (RJ45), 3x VARAN Out (RJ45), of which optionally 1x Ethernet VtE (RJ45) VARAN Out ports have automatic Ethernet recognition EtherCAT: 1x EtherCAT In (RJ45), 1x EtherCAT Out (RJ45) For synchronous data exchange, a triple buffer is provided. For asynchronous data exchange, CoE (CanOpen over EtherCat) and VoE (Vendor over EtherCat) is available.

VDM 086 –

8 digital short-circuit proof outputs (back-readable/+24 V DC/2 A) Can also be used as digital inputs (+24 V DC signal) 1x VARAN In (RJ45) 1x VARAN Out (RJ45) Linear topology possible

VI 021 VARAN

1x VARAN In* 1x VARAN Out (optional Ethernet (VtE))* Configuration in line structure possible

VSP 042 –

Profinet gateway (RJ45) allows integration of Profinet IRT drives Interface to primary VARAN participants or to the VARAN Manager over VARAN In (RJ45) For star, tree and linear topology: up to 4 stings (VARAN Out, RJ45) Tunneling IP packets over VtE VARAN transmits Ethernet (RJ45)    

VSP 044 –

Profinet gateway allows integration of Profinet IRT drives Interface to primary VARAN participants or to the VARAN Manager over VARAN In (RJ45) Voltage supply of downstream VARAN participants +24 V DC via Power over VARAN (PoV) For star, tree and linear topology: up to 4 stings (VARAN Out, RJ45) Tunneling IP packets over VtE VARAN transmits Ethernet (RJ45)    

VSP 045 –

Profinet gateway allows integration of Profinet IRT drives Interface to primary VARAN participants or to the VARAN Manager over VARAN In (RJ45) Voltage supply of downstream VARAN participants +24 V DC Power over VARAN (PoV), Norm UL248 For star, tree and linear topology: up to 4 stings (VARAN Out, RJ45) Tunneling IP packets over VtE VARAN transmits Ethernet (RJ45)

VSV 041 –

Interface to primary VARAN participants or to the VARAN Manager over VARAN In (RJ45) For star, tree and linear topology: up to 4 stings (VARAN Out, RJ45) Tunneling IP packets over VtE VARAN transmits Ethernet (RJ45)    

VSV 043 –

Interface to primary VARAN participants or to the VARAN Manager over VARAN In (RJ45) Voltage supply of downstream VARAN participants +24 V DC via Power over VARAN (PoV) For star, tree and linear topology: up to 4 stings (VARAN Out, RJ45) Tunneling IP packets over VtE VARAN transmits Ethernet (RJ45)    

GET IN TOUCH