- For evaluating measuring bridges (e.g. strain gauge load cells)
- 2 strain gauge inputs (16 bits)
- Measurement range 10 mV/V
Analog Inputs |
|
Type | strain gauge |
Number | 2 |
Resolution | 16 bits |
Measurement range | 10 mV/V |
Measurement precision | typically ±0.0565 % |
Conversion time per channel | ≤ 25 µs |
Hardware filter | 8 kHz (-3dB), -60 dB/decade |
Galvanic isolation | Yes |
Bridge supply voltage | 3,333 V DC |
Min. Bridge resistance | 100-5000 Ω |
Mechanical Features |
|
Dimensions | 42.2 x 27 x 91.3 mm (W x H x D) |
Article Number/Certification |
|
Article number | 18-001-282 |