CTI
I/O Systems
Products Overview
The SIGMATEK I/O Systems open all possibilities – whether in the control cabinet or directly in the field. DIAS stands for “Distributed Automation System”. All series, S-DIAS (IP20), P-DIAS (IP67) and X-DIAS (IP20) have a very high package density, are simple to use and can be flexibly combined.
P-DIAS
No products were found matching your selection.
S-DIAS
KL 091 –
Connection for +24 V DC supply with GND Supply distributed over 9 out-going +24 V DC supplies with GND 4 supply groups Short-circuit proof Current limited For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
KL 180 –
18x 0 V or ground at the contact points For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
KL 181 –
18x +24 V DC at the contact points For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
NC 100 –
1 incremental encoder Optional with TTL or RS422 signal (16 bits) Encoder power supply +5 V DC 4 digital inputs (+24 V DC/3.7 mA/10 µs) 4 digital outputs (+24 V DC/2 A) For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
PL 221 –
2 pixel LED strips with a maximum of 512 pixel RGB LEDs 2 +24 V PWM dimmable white LED strips For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
PSB 001 –
Expansion Module Supplies the downstreamed modules with power via the backplane bus For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
PVDM 087 –
4 digital inputs (+24 V DC/6 mA/6 ms) 4 digital short-circuit proof outputs (back-readable/+24 V DC/2 A) Can also be used as digital inputs (+24 V DC/6 mA/6 ms) 1x VARAN In (M12), 1x VARAN Out (M12) Protection type: IP67
PW 022 –
2 +24 V-switching PWM outputs with up to 1.5 A output current/channel Adjustable frequency in 0.5 μs increments between 30.5 Hz and 20 kHz Supply voltage +18-30 V DC For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
PW 161 –
16 digital outputs with 0.5 A or 8 with up to 1 A coil current for inductive loads Divided into 2 supply groups of 8 outputs each Supply voltage up to +48 V DC possible Per supply group, current measurement function integrated Fast switch-off electronics For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
RC 001 –
1x real-time clock Lithium battery For the S-DIAS system, EPLAN-Makros for simple control cabinet integration are available.
RO 041 –
4 relay outputs (normally open contacts) +24 V DC, 6 A or +230 V AC, 6 A For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
RO 051 –
5 relay outputs (changeover contacts) +24 V DC, 6 A or +115 V AC, 6 A For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SAI 041 –
4 safe analog current inputs SIL 3/PL e, Cat. 4 The S-DIAS safety analog input module provides the values of four analog current inputs from the Safe CPU (Safety CPU) For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SCP 111 –
Safety controller 1x USB device MicroSD slot Supports up to 16 safety-related I/O modules (total current 1600 mA) SIL 3/PL e, Cat. 4 The Safety controller is used to control the safety-related I/O modules and monitor the Safety logic. For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SCP 211 –
Safety controller 1x USB device MicroSD slot Supports up to 16 safety-related I/O modules (total current 1600 mA) SIL 3/PL e, Cat. 4 The Safety controller is used to control the safety-related I/O modules and monitor the Safety logic. For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SDI 101 –
10 safe digital inputs (+24 V DC/3.7 mA/0.5 ms) Doubled clock output signal (short circuit proof) SIL 3/PL e, Cat. 4 So that inputs can be tested and crossed circuits can be detected, 2 non-safe signal outputs, TA and TB, are provided. To use the SDI 101 in an application, a Safety CPU module is required. For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SDM 081 –
6 safe digital inputs (+24 V DC/3 mA/0.5 ms) 2 safe digital outputs (+24 V DC/2 A) Doubled clock output signal (short circuit proof) SIL 3/PL e, Cat. 4 So that inputs can be tested and crossed circuits can be detected, 2 non-safe signal outputs, TA and TB, are provided. To use the SDM 081 in an application, a Safety CPU module is required. For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SE 051 –
Ethernet switch with 5 ports (RJ45) For connection of network segments For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet
SE 052 –
Ethernet switch with 5 ports (Tyco Mini I/O) For connection of network segments For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SI 021 –
2 SSI absolute value encoders (max. 32 bits) Supports encoded and Gray encoded sensors For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SIB 061 –
6 safe digital inputs (+24 V DC/3 mA/0.5 ms) Double signal output (short-circuit proof) Cross-circuit detection SIL 3/PL e, Cat. 4 Decentralized reading of Safety signals directly on the machine, an operating console or on the back of the ETT multi-touch operating panels.
SNC 021 –
Provides values from 2 incremental encoders (up to 12 bits), Safety and standard CPU SIL 3/PL e, Cat. 4 Detection of various error types, such as cable break, cross circuit ... To use the SNC 021 in an application, a Safety CPU module is required. For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
SR 012 –
1 DC motor output stage (+50 V DC/0-5 A) 2 enable inputs +24 V/3 mA/0.5 ms with STO function (not EG type tested) 4 digital inputs +24 V/3.7 mA/5 ms 1 digital output +24 V/0.2 A/short-circuit protected For controlling a DC brush motor
SR 020 –
DC motor current controller (+12-30 V DC/0-3.5 A) Power LED driver (0-350 mA) LED driver (0-20 mA) For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.